Post
Topic
Board Hardware
Re: S-5 review. It has arrived some info is in!
by
ryanjf
on 04/01/2015, 15:42:14 UTC

I'm surprised that the discussion about replacement fans are more focused on their airflow volume (CFM) rather than static pressure (mm/H2O) which is more significant in heat sink/radiator applications.  High static pressure fans are more capable of penetrating through dense heat sink fins such as in the AntMiner devices.  I think there's a reason why Bitmain engineers equip their units with very powerful industrial 12038s with high static pressure (directly proportional to loudness) instead of just mainstream consumer-oriented 12025s.



true in the case of  one  push fan only.  but two high cfm fans as push pull get around that.

 since neither one needs full penetration of the heat sink using high static pressure,   but if you don't care about sound the stock fan with a good pull fan cools best.

Push-pull configuration is only effective in an enclosed unit (S3) and not in an open-chassis design (S5) though.



While that should absolutely be true, I can say in my experience the front heatsinks went from too hot to touch to cool to the touch with a high cfm pull fan installed on my S5's.