Board CPU/GPU Bitcoin mining hardware
Re: Mining accidents having caused physical damage (overheating hw, fires, etc)
by
OVerLoRDI
on 02/06/2011, 01:51:14 UTC
I'll start with one from a friend of mine (who shall remain anonymous): he lives in a place with old 120V electrical wiring. He put a rig of ~1.6kW (~13A), as measured by a kill-a-watt, on a 20A circuit for about half a day, until he started smelling smoke in his apartment, apparently coming from the wiring inside the walls. He completely stopped using this circuit, and now runs his rig on a dedicated 240V circuit. A 20A circuit is normally rated 16A for continuous loads by the National Electric Code, but that old wiring was likely defective and the insulation probably started melting.

That is makes me worry.  I am putting a lot of load on my old house wiring.  The electrics were redone sometime after grounded plugs became standard, but it is still very old.  Yay for 100+ year old houses...