I have plan to make change the fan adjust code base on the temp2 and temp3. so should be fixed in software
Mmmm, I see what you are talking about, interesting it could be you have a defective temp reader,
Let's move the temp3 to P3 and check if you are getting correct numbers on temp2 to confirm it is indeed a defective reader.
In the mean time also, to prevent the unit from overheating. you can shift the two adjustable fans to FAN4 and FAN5, which will run them at full speed ( could be a bit loud but it is a good temporary solution. )
and if temp2 also reports 0 after switching, then we can confirm that this is caused by a defective temp reader and we'll just mail you a new one.
BitSyncom, given the results posted above after performing the steps as you directed-- it appears there might be a problem with the Control Board. Would it be possible for me to obtain replacement Control Board?
Thanks.