Post
Topic
Board Madencilik (Alternatif Kripto-Paralar)
Re: Corsair HX Serisi Single ve Multiple Mod Farkı
by
OldToken
on 25/12/2017, 12:42:43 UTC
Arkadaşlar merhaba. Bilirsiniz bu power supply'da single ve multiple olarak ayarlamak için bir switch var. Madencilik için bu iki moddan hangisi seçmeliyiz ? Net olarak bir cevabını bulamadım. Bu arada 8 kartlı bir mining sisteminde kullanıyorum.


Glad to know. The difference between single or multiple rails is this:

Multiple rail: each trace is monitored separately, so if, say, one trace goes over 25A the power supply will shut down.

Single rail: all traces are monitored all together, so if the total current going through the +12V outputs goes over, say, 60A, the power supply will shut down. Alternatively, no OCP may be present at all on the +12V rail.

http://www.overclock.net/t/761202/single-rail-vs-multi-rail-explained