After this update for my D3 September Batch i did those confs:

Manual fan: 45%
Frequency: 475M
ASIC Voltage: Lowest

And i have a HW of 7384 in last 1hr
is this ok?


i would say its definitely not ok.
7384 per hour is to much...
actually i also working with the lowest voltage and i can run my d3's only with 400Mhz and one or two chains with 406Mhz with nearly no error 24/7, but thats it.