Hello, i have tested today the mod firmware for L3+ on one of my L3+ it work fine.
I have got the same performance of the other L3+ with standard firmware with a good energy saving from 840w to 710w at 400M and lowest voltage. near zero hw error for hours, statistics for this after 4 hours is 20 HW.
With a saving of about 900rpm over the fan with a performance option set.
For the temperature the moded L3+ is good , 2 point more respect the standard for the PCB a couple less respect the standard for the ASIC.

One question, why do you remove the safe parameter on the setup page 'Stop running when temprerature is over 80℃' ?

It is a good parameter can you add it please ? Smiley

It also will be nice to have a report of the time that every device will not mine on the owner of the system but for you, just for trasparency Smiley) I know that the pool show statistics but they aren't soo detailed for see 1.5% especially if done every 2 hours and not every 24 hours.

Thanks


great to hear it works good. I am not aware this 80 degree was an option so I accidently removed it. It's now enabled by default...

Hello, Just to be sure; Is the feature "reboot (and cool down) on too high temperatures (PCB temp > 85 deg celsius)" automatically active by default?

Best Regards


I am not aware this 85 degree was an option so I accidently removed it. It's now enabled by default...