I have two Monarchs that seem to have faulty temperature sensors and they stop hashing very quickly after bootup. Any way to fix the problem?
I have another with 15% HW error rate, any ideas on this?
15% error rate is not a big deal, a few engines are screaming but they don't really pull power. As long as it hashes well let it be.
As for the faulty temp sensors, are you sure the water blocks are running? Listen for the water at the radiator top, then check around to see if there are any signs of leaks around the water blocks/pumps.
C
I believe you are correct, sir.
I can hear fluid when I shake it, but I can't hear any fluid moving when I turn it on. I can tell at least one of the pumps initiates, but the copper blocks heat up immediately, some shares are accepted and then when the temp reaches 85 they shut down. Too little fluid perhaps. I have ordered new cooling units, I'll see if that fixes the issue.
Another issue, I have a 700gh unit that only hashes at 320gh with bfg 4.10 and 400 with BFL custom bfg 4.2. Could this be another cooling issue with one of the units shutting down?
I am having the exact same issue with my 700gh unit. What time s the other cooling unit u are ordering? Do you have a killawatt attached to see wattage draw? Mine seems to spike over 750 watt usage when I turn it on