Hi to everybody!
Need you help with Innosilicon A4+ LTCmaster miners:
Miner Type 17
Hw Version G19
Build Date Sat Dec 9 02:33:32 CST 2017
After one week of working it stopped working as wollows:
All green indicators are working but it does not mine and I can not connect web interface, just see the following:
I rebooted manu times, but no luck. What can I do? May be there is a possibility to upgrade a firmware through telnet?
P.S. One of miners lost one chain, but it was returned back after few reboots, firmware upgrade and clicking "Auto Search" button on "Voltage" block of "Miner General Configuration" tab.
P.S.S. sometimes miners shows huge Running time (above 14 or 17 thousands days!!!) it fixes by rebooting.
Thank you for any help.
You are running old FW and sounds like the issue with few people (incl. me) have had.
Try:
1) telnet to miner IP at port 8100
2) login: root
3) password: innot1t2
4) rm -rf /lib/python3.4/__pycache__/*.pyc
5) reboot
Hopefully you have working miner after this point, then go ahead and upgrade your firmware via web interface.
Link to the latest FW (as of 04.02.2018):
http://www.innosilicon.com.cn/download/update_180129.bin