Post
Topic
Board Hardware
Re: Hacking BFL Monarchs and servicing them while times are weird.
by
DaveF
on 26/03/2018, 12:12:45 UTC
apologies if this has been covered before.

i have a number of BFL Monarch.  they power up and run fine at idle.  within 5 minutes of mining the temps at 90C and cut off.  any ideas where i should start?


Thanks

Could be several things.

1) Cooling pump is dead so the fluid is not moving.
2) All the coolant leaked out (or was drained)
3) The cooling blocks are not solidly attached to the chips.

If you know someone with PC liquid cooling experience they can usually tell you in a few minutes if it's any of those. And for the most part #1 and #2 they are easily (if not cheaply) fixable. #3 is quick and simple but usually not the issue.

Did you get them used or have you had them since new? Did they ever work?

-Dave