Hi All, ---------------- Help Required ---------

I got my TP link router today, Flashed it with the Firmware from TechnoBit (0.1.0) configred everything as stated, SShed in to the thing, screen R and it is giving me a message about unable to to get the voltage settings (they are configured in the webpage) so i stop that process and start up CGminer normally and it detects the hardware but not hashing

 cgminer version 3.8.3 - Started: [2013-12-14 14:22:50]
--------------------------------------------------------------------------------
 (5s):0.000 (avg):0.000h/s | A:0  R:0  HW:0  WU:0.0/m
 ST: 2  SS: 0  NB: 1  LW: 96  GF: 0  RF: 0
 Connected to eu-stratum.btcguild.com diff 2 with stratum as
 Block: df06e698...  Diff:908M  Started: [14:22:50]  Best share: 0
--------------------------------------------------------------------------------
 [P]ool management ettings isplay options uit
 HEXb 0: 540  840/ 840mV | OFF   / 0.000h/s | A:0 R:0 HW:0/0.00% WU:0.0/m
 HEXb 1: 540  840/ 840mV |  0.000/ 0.000h/s | A:0 R:0 HW:0/0.00% WU:0.0/m
--------------------------------------------------------------------------------
 [2013-12-14 14:22:13] Started cgminer 3.8.3
 [2013-12-14 14:22:13] Started cgminer 3.8.3
 [2013-12-14 14:22:49] Pool 0 difficulty changed to 2
 [2013-12-14 14:22:49] Probing for an alive pool
 [2013-12-14 14:22:50] Network diff set to 908M
 [2013-12-14 14:22:50] HEXb 0 failure, disabling!
 [2013-12-14 14:22:55] Hotplug: hexminerb added HEXb 1

What does it mean failure disabling? Is this indicating a hardware issue?  The miner is plugged directly in to the TP. Power by molex off a PC

I got a second miner I not opened, maybe I should try that one

Sidenote:Thank you Zich for posting on my behalf yesterday


Hey check your molex, PSU and use multimeter to see if it is giving 12V. In order for psu to start without PC you have to short green and black wires on 24pin motherboard connector. In your case just turn on the PC  Wink

This usually happens when there is a problem with 12V power
----------------------
I got my TP link router today, Flashed it with the Firmware from TechnoBit (0.1.0) configred everything as stated, SShed in to the thing, screen R and it is giving me a message about unable to to get the voltage settings
---------------------------------
Not normal hit sav+apply on web page it will solve this issue i guess it is ok already

PS:
Same issue just a couple of posts above yours

https://bitcointalk.org/index.php?topic=307897.msg3958562#msg3958562