Post
Topic
Board Mining support
Re: T17 soc init failed
by
thierry4wd
on 17/03/2022, 17:23:36 UTC
When your antminer T17 is reading 'soc connect failed , kill all hashboard. It is usually because one or more of your heat sink is lose but has not fallen off yet. So you need to detach the lose heat sink and use super glue to fix it properly. If my suggestion helps you and you want to donate bitcoins to me, please send it to this address:
36Erg6tTtLjeRcc812KVF96Y4W4ZiqH7pn


NO , this message " 2021-11-01 13:05:33 driver-btm-api.c:205:set_miner_status: ERROR_SOC_INIT " group all problem, temp sensor, bad chip, bad pool, pool dead...

I see : " 2021-11-01 13:05:33 driver-btm-api.c:1897:bitmain_board_init: ERROR: None of the chains exist " ... SO ! need check ALL the ribon cable ! or maybe psu .