Post
Topic
Board Mining software (miners)
Topic OP
XP Error
by
Tsub
on 24/09/2022, 03:37:39 UTC
I am troubleshooting an issue with 2 of my XP's. 

What is weird is that usually, if you have a hashboard issue, you can unplug it and the S19 will run with 2.  With an XP, when you unplug it, it throws a different error.

Here is the part that throws the error.  I can post the full log if you really need it.

Any insight / best guesses / etc  would be appreciated.

2022-09-24 02:27:49 Initializing the power, please wait, this may take up to 2 minutes...
2022-09-24 02:28:19 Slept 30 seconds, diff = 2.
2022-09-24 02:28:29 set_voltage_by_steps to 1500.
2022-09-24 02:28:31 bad chain id = 3
2022-09-24 02:28:35 start up min temp by 75a = 45
2022-09-24 02:28:37 Chain[0]: find 110 asic, times 0
2022-09-24 02:28:39 Chain[1]: find 110 asic, times 0
2022-09-24 02:28:41 Chain[2]: find 3 asic, times 0
2022-09-24 02:28:43 Chain[2]: find 3 asic, times 1
2022-09-24 02:28:45 Chain[2]: find 3 asic, times 2
2022-09-24 02:28:45 Chain 2 only find 3 asic, will power off hash board 2
2022-09-24 02:28:45 ERROR_SOC_INIT: soc init failed!
2022-09-24 02:28:45 stop_mining: soc init failed!
2022-09-24 02:28:45 uninit_temp_info
2022-09-24 02:28:45 do not read temp anymore...
2022-09-24 02:28:45 cancel thread
2022-09-24 02:28:45 ****power off hashboard****
2022-09-24 02:28:45 power off
2022-09-24 02:28:46 temp monitor thread exit
2022-09-24 02:28:56 Version num 65536
2022-09-24 02:28:56 Mask num 0x1fffe000
2022-09-24 02:28:56 Note: addrInterval or corenum is not initialized.