Re: T15 socket connect failed: connection refused
by
MinerMEDIC
on 14/10/2022, 06:13:35 UTC
It is not inconceivable for a bad fan to cause a connection error. Each control board has a Minimum of four voltage sources plus the fan power supply. Being so tightly interconnected it is possible for a short in the fan to cause a brown out or voltage drop somewhere else in the control board leading to a unexplained error. Try fans plugged in one at a time, maybe even different locations. Let us know how that goes.