So, point is that these do get hot and for people with 1 or 2 they may not be able to cool it adequately and not everyone wants to host their miners.

I plan to host 3 sp10 and 3 sp30. I will cool it with air from the house (~20°C atm) and when temp will get higher i will buy an AC for the house. I will put it in a very small room but with high air flow. In add off, i don't plan to stock those appliance horizontal but vertically with a big fan on bottom and big extractor on top.
I believe that it will be good for several reason :
- heat goes up
- horizontal fan make less noise
- easier for me to stack it (the room is very tiny)

Here my plan :


The grey part will be stick to the appliances with a hole to make place for power supplies (I plan do to twice shown on picture).
The fan on bottom is... a fan, nothing more Cheesy
The air extractor will be something like this : http://www.cultureindoor.com/1299-extracteur-winflex-vk-100-mm-250-m3-h.html
Notice it's from a growshop, they do great pricing.

My last concern is about the bottom of appliance getting hot. I guess i will put 1/2 cm between each appliance and let the fan/extractor do the rest.

Last but not least, i hate the noise. really, badly, whatever... :@
So, i will isolate the door (got some good experience there) and catch the noise with self-adhesive acoustic foam. Already found some very good foam with an α (alpha Sabine) over 0.80 for frequency over 2kHz.

Of course, I've already installed the smoke detector, just in case off :p

Tell me what you think and, SP-T, please tell me if putting the miners vertically is a problem...

Regards,

PS:i shall be delivered on monday, tuesday, so expect pictures soon Smiley

I think it's OK, but I will consult the board guys day after tomorrow (we have Passower holidays still). You can mail me at zvi@spondoolies-tech.com if something doesn't work on the SW side. We did some testing with acoustic foam chimney, it is possible and does help with the noise but you really need to know what you are doing because if you do it wrong you can burn your house. We do not encourage it and take no responsibility if something happens, but it is your miner Smiley

I am not sure that you will need the fan at the bottom, as long as there is good air flow in front and in back it will suck all the air it needs. The SW should protect the miner from overheating by downscaling voltage and then stopping the miner.