Post
Topic
Board Mining support
Re: New S19k Pro Stopped Working after 1 week
by
tuaris
on 08/01/2025, 18:45:21 UTC
Applied a firmware update (Antminer-S19k-Pro-merge-release-20240409060820.bmu), now I get:

Code:
2025-01-08 18:42:54 pulse_mode = 1, ccdly_sel = 0, pwth_sel = 4
2025-01-08 18:42:54 start do_core_reset
2025-01-08 18:43:06 end do_core_reset
2025-01-08 18:43:06 noraml inc freq voltage
2025-01-08 18:43:06 set_voltage_by_steps to 1500.
2025-01-08 18:43:10 Version num 65536
2025-01-08 18:43:10 Mask num 0x1fffe000
2025-01-08 18:43:10 opt_multi_version = 65536, interval timeout = 2620657
2025-01-08 18:43:10 freq = 590, percent = 90, hcn = 4442, timeout = 2620657
2025-01-08 18:43:10 (null)
2025-01-08 18:43:21 freq 200 waiting board temp to 35,curr temp 24
2025-01-08 18:43:23 Error, fan lost, only find 3 (< 4)
2025-01-08 18:43:23 fan_id = 0, fan_speed = 1990
2025-01-08 18:43:23 fan_id = 1, fan_speed = 0
2025-01-08 18:43:23 fan_id = 2, fan_speed = 2400
2025-01-08 18:43:23 fan_id = 3, fan_speed = 2400
2025-01-08 18:43:23 Sweep error string = F:1.
2025-01-08 18:43:23 ERROR_FAN_LOST: fan lost
2025-01-08 18:43:23 stop_mining: fan lost
2025-01-08 18:43:23 uninit_temp_info
2025-01-08 18:43:23 do not read temp anymore...
2025-01-08 18:43:23 cancel thread
2025-01-08 18:43:23 cancel thread
2025-01-08 18:43:23 ****power off hashboard****
2025-01-08 18:43:23 power off
2025-01-08 18:43:25 temp monitor thread exit
2025-01-08 18:43:31 freq 200 waiting board temp to 35,curr temp 24
2025-01-08 18:43:42 Sweep error string = P:2.
2025-01-08 18:43:42 ERROR_TEMP_TOO_LOW: protect machine!
2025-01-08 18:43:42 stop_mining: protect machine!
2025-01-08 18:43:42 ****power off hashboard****
2025-01-08 18:43:42 power off

So I got a unit with a bad fan? Is the ASIC fine?