I'm having the some trouble with the Vreg it seems also, what SMD cap size was it?

Perhaps I'll take mine apart and take a look.

Code:
₿ (195878) power_management: Temp: 52.0°C, SetPoint: 60.0°C, Output: 25.0%
₿ (195888) TPS546: Status: 0x4851
₿ (195888) TPS546: The voltage regulator is turned off
₿ (195898) TPS546: An output overcurrent fault has occurred
₿ (195908) TPS546: TPS546 IOUT Status: A0
₿ (195908) TPS546: IOUT Overcurrent Fault
₿ (195908) TPS546: IOUT Overcurrent Warning
₿ (195918) TPS546: The output voltage is NOT within the regulation window. PGOOD pin is asserted.
₿ (196088) bm1366Module: Job ID: 28, Core: 0/5, Ver: 01EDA000
₿ (196098) asic_result: Ver: 21EDA000 Nonce 56E9E300 diff 286.9 of 10000.
₿ (196568) bm1366Module: Job ID: 28, Core: 1/6, Ver: 062CC000
₿ (196568) asic_result: Ver: 262CC000 Nonce 3513E302 diff 5450.3 of 10000.

I don't know the SMD size, but the resistance value measured after replacement is about 9.08K
The result is obtained by measuring the same capacitor in three VR groups.
It is recommended to measure the resistance and capacitance near VR. If the values ​​are different, there is a problem.
Version 1
Scraped on 19/05/2025, 21:51:54 UTC
I'm having the some trouble with the Vreg it seems also, what SMD cap size was it?

Perhaps I'll take mine apart and take a look.

Code:
₿ (195878) power_management: Temp: 52.0°C, SetPoint: 60.0°C, Output: 25.0%
₿ (195888) TPS546: Status: 0x4851
₿ (195888) TPS546: The voltage regulator is turned off
₿ (195898) TPS546: An output overcurrent fault has occurred
₿ (195908) TPS546: TPS546 IOUT Status: A0
₿ (195908) TPS546: IOUT Overcurrent Fault
₿ (195908) TPS546: IOUT Overcurrent Warning
₿ (195918) TPS546: The output voltage is NOT within the regulation window. PGOOD pin is asserted.
₿ (196088) bm1366Module: Job ID: 28, Core: 0/5, Ver: 01EDA000
₿ (196098) asic_result: Ver: 21EDA000 Nonce 56E9E300 diff 286.9 of 10000.
₿ (196568) bm1366Module: Job ID: 28, Core: 1/6, Ver: 062CC000
₿ (196568) asic_result: Ver: 262CC000 Nonce 3513E302 diff 5450.3 of 10000.

I don't know the SMD size, but the resistance value measured after replacement is about 9.08K
It is recommended to measure the resistance and capacitance near VR. If the values ​​are different, there is a problem.
Original archived Re: Lucky Miner LV08 - Firmware
Scraped on 19/05/2025, 21:47:04 UTC
I'm having the some trouble with the Vreg it seems also, what SMD cap size was it?

Perhaps I'll take mine apart and take a look.

Code:
₿ (195878) power_management: Temp: 52.0°C, SetPoint: 60.0°C, Output: 25.0%
₿ (195888) TPS546: Status: 0x4851
₿ (195888) TPS546: The voltage regulator is turned off
₿ (195898) TPS546: An output overcurrent fault has occurred
₿ (195908) TPS546: TPS546 IOUT Status: A0
₿ (195908) TPS546: IOUT Overcurrent Fault
₿ (195908) TPS546: IOUT Overcurrent Warning
₿ (195918) TPS546: The output voltage is NOT within the regulation window. PGOOD pin is asserted.
₿ (196088) bm1366Module: Job ID: 28, Core: 0/5, Ver: 01EDA000
₿ (196098) asic_result: Ver: 21EDA000 Nonce 56E9E300 diff 286.9 of 10000.
₿ (196568) bm1366Module: Job ID: 28, Core: 1/6, Ver: 062CC000
₿ (196568) asic_result: Ver: 262CC000 Nonce 3513E302 diff 5450.3 of 10000.

I don't know the SMD size, but the resistance value measured after replacement is about 9.08K