Re: BITMAIN‘s Liquid Cooled Miner C1: It is not only cool, but it is cool
by
dogie
on 16/10/2014, 20:12:53 UTC
How would you run 5 independent loops off a single channel radiator?
In series, just like I used to do with 4x GPUs. Can easily dissipate 800W+ of heat on the standard 240 rad I was using back then.

We don't have 800W of heat, we have 5KW of heat - you simply cant get the flow rate required to do that in series before you get to the radiator due to the internal diameter of the tubing [and pathways in the heatsinks].

You also dont need "specialized" coolant for any sort of watercooling, distilled water changed regularly will work just as well, at $.99 per gallon at your local store if that much.

As usual, I recommend the safe options because lets be honest, what percentage of people are going to decide to spend a few hours to drain, flush, clean and refill their multiple C1s?