If you are writing about ASICs with hydrocooling, then look at the engineers' reviews about them. The quality of standard containers is not the best, and after several serious mistakes, engineers come to the conclusion that they need to make their own solutions.
When you say 'the quality of standard containers is not the best,' do you mean like prefab Bitmain antboxes or similar hydro containers, dry coolers/heat exchanger or like the chassis of the miner itself?
Where would I go to see engineer reviews you mention?
Also anyone here have info on the chip specs for the S23 or any more details about hashboard/power supply design?
in looking at this s23
Detailed Characteristics Value
Power Supply
Phase 3
Input voltage, Volt(2-1) 380~415
Input frequency range, Hz 50~60
Input max current, Amp 12
Hardware Configuration
Networking connection mode RJ45 Ethernet 10/100M
Server size (length*width*height, w/o package), mm 410*170*209
Server size (length*width*height, with package), mm 570*316*430
Net weight, kg 13.5
Gross weight, kg 14.8
Environment Requirements
Inlet coolant temperature, °C 20~50
Coolant flow, L/min 8.0~10.0
Coolant pressure, bar ≤3.5
Working coolant(3-2) Antifreeze/Pure water/Deionized water
Coolant pH value Antifreeze: 7.0~9.0
Pure water: 6.5~7.5
Deionized water:8.5~9.5
Diameter of coolant pipe connector, mm OD10
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%
Notes:
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
(1-2) Inlet coolant temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual", Chapter 9, Article 3, Point 6, "Maintenance of Coolant"!
this is a container that should work
https://www.youtube.com/watch?v=3VDua9W7e48