I have 4 x S3 antminers . I had the 10/24 firmware on them seems like MY GHS was dropping from 450 to 340+ but never going back up to 450 or even close any ideas. When I reboot the GHS jumps back up for about 10-12HRs then back down again. All set at s3+ default 225. I changed the voltage to 0770. I just installed Doges firmware on one of them to try it. Any one has any ideas it would be greatly appreciated. Thanks in advance.
I know I am quoting myself but it looks like 0720 is normal voltage for 10/24 firmware running 225 Freq and 0725 for Dogies 12/19 Firmware at 225 Freq looks right. I will have to let them run for 24hrs and see what happens. Might have to go with the 12/19 firmware if everything keeps running okay because it looks like the 12/19 is running better then the 10/24 . Ill keep everyone posted. Thanks  

My question would be, if the wattage is not changing at the wall, is it doing anything at all???

edit: referencing the voltage.. changing the freq definitely changes the watts at the wall